A New Two-in-One Insulin Pump Shows Promise for Blood Sugar Control in Chinese Adults

A real-world study of a flexible insulin pump system found that most adults using it achieved good blood sugar control and reported improvements in quality of life. However, low blood sugar events remained a concern for some users.

PubMed indexed literature

Evidence label explains the kind of source behind this article (for example peer-reviewed literature vs community video). It is not medical advice.

living with t1dmental healthtechnologysupport

Key takeaways

  • Adults using the Ari two-in-one pump achieved an average HbA1c of 7.2%, with about three-quarters of the day spent in target blood sugar range
  • More than half of patients reported fewer hypoglycemic (low blood sugar) and hyperglycemic (high blood sugar) episodes compared to their previous therapy
  • Nearly 77% of users experienced meaningful improvements in overall quality of life, and 79% felt the pump was comfortable to wear
  • The pump's dual design—switchable between a patch-on tubeless form and a tubed portable form—offered flexibility that appealed to different users
  • Low blood sugar events occurred more frequently than clinical targets recommend, suggesting this remains an area for continued attention

What This Study Looked At

Researchers in China studied real-world use of a new insulin pump model called the Ari two-in-one pump in 47 adults with type 1 diabetes. The pump is distinctive because it can switch between two forms: a tubeless patch that sticks directly to skin, and a more traditional tubed pump. Each form is available with either standard or short cannulas, giving users options based on their preference and lifestyle.

Over at least three months of use, patients answered surveys about their blood sugar management, quality of life, comfort, and overall experience with the pump. The researchers collected self-reported data and analyzed the results to understand how well the pump worked and how patients felt using it.

Blood Sugar Control Results

Patients using the Ari pump achieved an average HbA1c of 7.2%, which reflects their average blood sugar control over the study period. When researchers looked at continuous glucose monitor data, they found that patients spent 74% of their time with blood sugar in the target range of 3.9 to 10.0 mmol/L (roughly 70–180 mg/dL).

About 18% of the time, blood sugar was above the target range, and 8% of the time it was below target. These percentages met clinical goals for high blood sugar, but the low blood sugar time was higher than recommended targets, meaning hypoglycemia (low blood sugar events) remains a challenge for some users.

When comparing their experience with the pump to their previous treatment, 55% of patients reported fewer low blood sugar episodes, and 53% reported fewer high blood sugar episodes. This suggests the pump helped many people reduce problematic blood sugar swings.

Quality of Life and User Experience

Beyond blood sugar numbers, researchers asked patients how the pump affected their daily lives. Nearly 49% said they felt more confident in their treatment and experienced greater freedom in their daily activities. This kind of confidence and flexibility can be important for people managing a condition that requires constant attention.

The majority of patients—79%—reported better wearing comfort with the pump compared to previous methods, and 77% experienced meaningful overall improvement in their quality of life. These findings suggest that the pump's design and flexibility appealed to many users and made managing diabetes feel more manageable.

What This Means

This real-world study demonstrates that the Ari two-in-one pump helped a group of Chinese adults achieve reasonably good blood sugar control while also improving their sense of confidence and quality of life. The pump's ability to switch between tubeless and tubed forms appears to have given users options that suited different situations and preferences.

At the same time, the study shows that low blood sugar events occurred more frequently than clinical guidelines recommend, indicating there is still room for improvement in preventing hypoglycemia. Because this study was conducted in China, the findings may reflect the experiences of that population specifically; results in other regions or populations might differ.

The data comes from patients' own reports rather than objective measurements of all factors, so the results tell us about real-world experiences but cannot establish cause-and-effect relationships as rigorously as controlled trials might. Individuals considering any insulin pump should discuss options, expected outcomes, and potential risks with their diabetes care team.

Evidence label

Source: Diabetology & metabolic syndrome. Evidence type: PubMed indexed literature. Type1Cure is an information and intelligence hub, not a medical advice service. This article summarizes published research and does not provide diagnosis, treatment, or personal medical guidance. Always talk to your own care team before changing anything about your Type 1 diabetes management.